(1) Cable length
When using the unit connection cable, junction cable, and extension cable together, the sum of the
length for all type of cables must be 30 m or less. This limitation is applicable to each the transmitter
and receiver respectively. Since up to 3 SL-V units can be connected in series, up to 2 sets of series
connection cables are required. Two sets of the SL-VS10 (cable length: 10 m) cables can be used.
In this case, the sum of the length of all type of cables, including the series connection cable, must
be 50 m or less. This limitation is also applicable to each transmitter and receiver respectively.
Cables must be within the lengths specified. Failure to follow this specification may cause
improper operation of safety function, and may cause dangerous situation.
The series connection cable cannot be cut or extended. If the cable is cut or extended, safety
features may not operate properly. Do not allow this to happen as it is extremely dangerous.
(2) Minimum cable bending radius : 5 mm
(3) Identification of connector cables
Cables can be identified by the colors of their connectors and their cable insulation.
1. Cable Insulation colors
Cables for Transmitter : Cable insulation in grey
Cables for Receiver : Cable insulation in black
2. Connector colors
PNP output type cables : Black connectors
NPN output type cables : Grey connectors
Series connection cables : Black connectors
Be sure to connect the unit connection cable for receiver to the SL-V receiver and the unit connection
cable for transmitter to the SL-V transmitter.
Simple function type
Multi-function type
When the muting bank function is used, the pin assignment changes as follows.
Pink: muting bank input 3, purple: muting bank input 1, red/black: muting bank input 2
M12 connector male pin assignment M14 connector male pin assignment
1
The unit connection cable for transmitter (cable insulation is grey) must be connected to the transmitter as shown below. Sim-
ilarly, the unit connection cable for receiver (cable insulation is black) must be connected to the receiver as shown below.
Recommended tightening torque : 0.3 N·m
Minimum cable bending radius : 5 mm
For SL-VF, VH, and VL
Transmitter Receiver
For SL-VFM, VHM, and VLM
Transmitter Receiver
Do not remove the grey gasket installed on the connector. This gasket is necessary to ful-
fill the requirement of IP65 or IP67.
Connect the unit connection cable to the connector receptacle on the lower part of the SL-
V. Removing the connector cover on the upper part of the SL-V and connecting the unit
connection cable may result in an SL-V failure.
2
For the SL-VHM, ferrite core is not required. However, for the SL-VF, SL-VH, SL-VL, or SL-VLM, one
ferrite core must be put on the SL-V unit connection cable for the transmitter. On the other hand, for
the SL-VFM, two ferrite core must be put on the SL-V unit connection cable for the receiver.
*1 The side where the connector cover has already been installed at shipment is the top side.
Beam center-line : An optical path joining the optical center of the emitting element on the transmit-
ter to the optical center of the corresponding receiving element on the receiver.
the SL-V must be installed so that the beam center-line mark on the transmitter
and that on the receiver face one another and are located at the same height.
Detection height : The height from the top beam center-line to the bottom beam center-line (length).
Protection height : An object approaching the detection zone from the top of the detection height is first
detected at point A, which is the distance of the detection capability from the top of the
detection height. The equivalent position on the bottom is called point B. The height from
the top edge of the specified detection capability that exists at point A to the bottom edge
of the specified detection capability that exists at point B is called a "protection height".
The following calculation formula can be defined:
Protection height = "Detection height" + 2 x "the specified detection capability"–"beam axis diameter".
*
Refer to the following diagram for an explanation of beam center-line, detection height and protection height.
Cable specification
Connector pin assignment
Transmitter Receiver
Pin No. Wire color Assigned function Pin No. Wire color Assigned function
1PinkInterlock mode selection input 1WhiteOSSD 2
2Brown+24 V 2Brown+24 V
3VioletWait input 3BlackOSSD 1
4GreenInterlock-reset-ready output 4YellowRESET input
5 Orange Communication cable 1 (RS485_+) 5OrangeCommunication cable 1 (RS485_+)
6
Orange/
Black
Communication cable 2 (RS485_-) 6
Orange/
Black
Communication cable 2 (RS485_-)
7Blue0 V 7Blue0 V
8RedAUX (auxiliary) output 8RedEDM input
Transmitter Receiver
Pin No. Wire color Assigned function Pin No. Wire color Assigned function
1PinkInterlock mode selection input 1WhiteOSSD 2
2Brown+24 V 2Brown+24 V
3VioletWait input 3BlackOSSD 1
4GreenInterlock-reset-ready output 4YellowRESET input
5 Orange Communication cable 1 (RS485_+) 5OrangeCommunication cable 1 (RS485_+)
6
Orange/
Black
Communication cable 2 (RS485_-) 6
Orange/
Black
Communication cable 2 (RS485_-)
7Blue0 V 7Blue0 V
8RedAUX (auxiliary) output 8RedEDM input
9GreyState information output 1 9Red/BlackOverride input
10 Grey/Black State information output 2 10
Ye l l o w /
Black
Muting lamp output
11 Pink/Black Alert output 11 Light blue Muting input 1
12
White/
Black
Clear/Blocked Output 12
Light blue/
Black
Muting input 2
Danger
2. Connector
1. Cable insulation
NOTE
Reference
6
10
11 12
9
8
7
12
3
4
5
5
83 7
6
1
2
4
Cable connection
Part Description
grey
M2.6
screw
black
M2.6
screw
Push the cable
into the
g
roove.
Push the cable
into the groove.
Detection
surface
Detection
surface
grey
M2.6
screw
Push the cable
into the
g
roove.
black
M2.6
screw
Push the cable
into the
g
roove.
Detection
surface
Detection
surface
Caution
Within 200 mm
Ferrite core
(diameter: 18.5 mm, length: 34 mm)
Unit connection cable
Transmitter
Within 250 mm
Ferrite core
(diameter: 18.5 mm, length: 34 mm)
Unit connection cable
Receiver
For SL-VF, SL-VH, SL-VL, SL-VLM (Ferrite core x 1)
Attach to the transmitter
For SL-VFM (Ferrite core x 2)
Attach to the receiver
Connector cover
Connector
receptacle
Detection
surface
Detection
surface
LEVEL
LEVEL
MUTE1
MUTE2
OSSD
INTER
LOCK
WAIT
FUNCTION
OSSD
INTER
LOCK
ø25 (0.98")
ø25 (0.98")SL-V08H
SL-V08H
1
2
3
4
5
1
2
3
4
5
Detection
surface
Connector receptacle
Beam center-line mark
(lower)
Beam center-line mark
(upper)
Indicators
Detection
surface
Bottom
To p
Connector cover
Installation reference mark
Installation reference mark
*
1
SL-V main unit
ReceiverTransmitter
ReceiverTransmitter
The connector and connector cover for
the SL-VFM, VHM, and VLM are located
on the back side.
Specified detection capability (position A)
Specified detection capability (position B)
Protection heightDetection
height
Beam center-line
Beam center-line mark
a
a: Beam axis spacing
b: Beam axis diameter
c: Detection capability
b
c
Page view 2
1 2 3 4 5 6 7 8 9 10

Comments to this Manuals

No comments