Keyence DL-CL1 User Manual Page 12

  • Download
  • Add to my manuals
  • Print
  • Page
    / 74
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 11
1-2
1
Before Using
- CC-Link Compatible Network Unit DL-CL1 User’s Manual (FD-S) -
1-1
DL-CL1 Overview
This unit operates as a remote device station (Ver. 1.1 and 2 switchable) of a CC-Link
system. Using CC-Link communications, the sensor amplifiers and other units con-
nected to the DL-CL1 can transmit their ON/OFF control signals and current values as
communication data to PLC or other equipment.
The DL-CL1 supports cyclic transfer and extended cyclic transfer, enabli
ng data com-
muni
cation without the need of a ladder program. In addition, remote input/output sig-
nals can be used as handshake signals to read/write settings of sensor amplifiers and
to execute motion commands on the sensor amplifiers.
System configuration example
Number of Connectable Sensor Amplifiers
*Cannot b e connected to a pane
l mounting type.
The DL-CL1 can connect multiple sensor amplifiers (a single main unit and multiple
expansion units) which support D-Bus. "D-bus" is the name of KEYENCE's wiring-
saving system for sensor amplifiers.
Different types of sensor amplifiers with D-bus support can be connected to the single
DL-CL1 unit.
How many and what different types of sensor
amplifiers
can be connected depends
on the sensor amplifiers or units to be connected. Please inquire for details.
Overview
PLC or other host device
(CC-Link master unit)
DL-CL1 (This unit)
D-bus compatible sensor amplifier
CC-Link slave
Types and Number of Connectable Sensor Amplifiers
Name Amplifier form Main unit
Expansion
unit
Maximum number of
connectable units
FD-S
Series*
DIN rail
mounting type
FD-SA1NA
FD-SA1PA
FD-SA2NA
FD-SA2PA
4
(1 main unit, 3 expansion units)
Page view 11
1 2 ... 7 8 9 10 11 12 13 14 15 16 17 ... 73 74

Comments to this Manuals

No comments