96
6.3 Minimum Input Time and Output Response Time
This section describes the minimum input time and the output response time of the
EX-V series.
Minimum input time
The minimum input time required for the TIMING, HOLD RESET, ZERO, OUTPUT
DISABLE and EXT1/EXT2 is as follows:
TIMING and HOLD RESET
ZERO, OUTPUT DISABLE and EXT1/EXT2
SYNC
Note: The minimum input time does not include the processing time after the signal
is received.
ON: 1.5 ms
OFF: 1.5 ms
ON
OFF
ON: 15 ms
OFF: 15 ms
ON OFF
3 ms min. 13 ms min.
2.5 ms 2.5 ms
2 ms
12.5 ms
ON
OFF
ON
OFF
ON
OFF
SYNC input
Measurement
Sensor head oscillation
Page view 105