Digital Calibration Fiberoptic Sensors
FS-V1(P)
Instruction Manual
Read this manual before using the product in order to achieve maximum performance.
Keep this manual in a safe place after reading it so that it can be used at any time.
PART NAMES AND FUNCTIONS
*Use the UP/DOWN key together with the MODE selector button.
PRECAUTIONS ON REGULATIONS AND STANDARDS
UL Certificate
This product is an UL/C-UL Listed product.
UL File No. E301717
Category NRKH,NRKH7
Enclosure Type 1 (Based on UL50)
Be sure to consider the following specifications when using this product
as an UL/C-UL Listed Product.
Use the power supply with Class 2 output defined in NFPA70 (NEC:
National Electrical Code).
Power supply/ Control input/ Control output circuits shall be con-
nected to a single Class 2 source only.
Use with the over current protection device which is rated 24 V or
more and not more than 2 A.
SPECIFICATIONS
1 A "P" following the model number indicates PNP-output type.
2 When several units are connected, the allowable ambient temperature changes depending
on the following conditions. To connect several units, be sure to mount them to a DIN rail
(metal DIN rail). Make sure that the output current is 20 mA. max.
When 3 to 10 units are connected: -10 to +50 °C
When 11 to 16 units are connected: -10 to +45 °C
SELECTING DISPLAYED DATA
Displaying excess gain
Received light intensity is converted by defining
the setting value as 100 P (%).
Stable LIGHT status is obtained with 110 P (%) or more.
Stable DARK status is obtained with 90 P (%) or less.
You can adjust the sensitivity in increments of 1%.
¨ Refer to P.2.
Displaying received light intensity
Received light intensity is displayed approxi-
mately 4000 is the maximum setting.
Note: The MAX and MIN values vary depending on the fiber unit con-
nected.
Displaying a setting value
The current setting value is displayed. You can adjust the setting value
in increments of 1 .
¨ Refer to P.2.
It indicates a hazardous situation which, if not avoided,
could result in death or serious injury.
It indicates a situation which, if not avoided, could result in
product damage as well as property damage.
96M11226
Warning
NOTICE
#
2
AB
MODE
SET
CH
Output timer selector switch UP/DOWN key
Changes sensitivity setting value.
Selects channel (expansion unit).
MODE selector button
• Selects displayed data.
Excess gain
Light intensity
Setting value
Selects channel (expansion unit). *
• Enables/disables key protect. *
OFF-delay 40 ms
ON-delay 40 ms
Timer OFF
Note: Outputs of both A and B
are set to the same mode.
Calibration
indicator
Output A
indicator
Output B
indicator
Output selector switch
DARK-ON for both outputs
A and B
LIGHT-ON for output A and
DARK-ON for output B
LIGHT-ON for both outputs
A and B
SET button
Sets sensitivity.
LCD display monitor
Turns display red when the
selected channel is ON.
Turns display green when the
selected channel is OFF.
This product is just intended to detect the object(s). Do
not use this product for the purpose to protect a human
body or a part of human body.
This product is not intended for use as explosion-proof
product. Do not use this product in a hazardous
location and/or potentially explosive atmosphere.
Accessories
Instruction manual (x 1)
Mounting bracket (x 1)
Model NPN output
FS-V1
PNP output
FS-V1P
Light source Red LED
Response time 250 μs
Operation mode LIGHT-ON/DARK-ON (switch-selectable)
Indicators
Output indicators: 2 Red LED’s,
Calibration indicator: Yellow LED,
Received light intensity display: LCD (Red/Green LED back-lit)
Timer function ON-delay: 40 ms, OFF-delay: 40 ms,
Timer OFF (switch selectable)
External calibration
input signal
contact, solid state
Control output
(2 outputs)
NPN or PNP open-collector 24 V 100 mA max.,
Residual voltage : 1 V max.
Protection circuit Reverse polarity protection, Over-current protection,
Surge protection
Power supply voltage 12 to 24 VDC ±10%, Ripple (P-P) 10% max., Class 2
Current consumption 50 mA max.
Ambient illumination Candescent lamp: 10,000 lx max., Sunlight: 20,000 lx max.
Ambient temperature -10 to +55°C (14 to 131°F), No freezing
Relative humidity 35 to 85%, No condensation
Vibration 10 to 55 Hz, 1.5 mm double amplitude in X, Y and
Z directions for two hours
Shock immunity 500 m/s
2
in X, Y and Z directions,
three times each
Housing material Body/Cover: Polycarbonate
Weight Approx. 80 g (including 2 m cable)
Warning
#
2
CH
#

CH
#

CH
MODE
MODE
MODE
Excess gain (%)
Setting value (4 digits)
Press this
button once.
Hold down this button
for longer than 3 seconds.
Received light intensity
(4 digits)
* The setting value flashes on and off.
Press this
button once.
Channel display:
Indicates the
channel of the
expansion unit
currently being
monitored.
(Factory-setting is Excess gain.)
# 2
CH
# 
CH
Page view 0
1 2 3 4

Summary of Contents

Page 1 - FS-V1(P)

1Digital Calibration Fiberoptic SensorsFS-V1(P)Instruction ManualRead this manual before using the product in order to achieve maximum performance.Kee

Page 2 - CHANGE THE SETTING VALUE

2SETTING SENSITIVITYSelect the sensitivity setting procedure according to the target condi-tion.For sensitivity adjustment using a moving targetz Full

Page 3 -  Mounting EXPANSION units

3CONTROL AN EXPANSION UNIT [FS-T2(P)]1. To change the channel, press [UP] (or [DOWN]) while holding [MODE].Select the channel for the expansion unit [

Page 4 - 3. PRODUCT APPLICABILITY

4SETTING 2 INDEPENDENT OUTPUTSThe FS-V1(P) allows you to set two types of sensitivity (tolerance indi-vidually.To change the channel, press [UP] or [