. Default Mode Settings (Initialization)
The sensor ships with the following configuration.
Detection mode
Operating mode
N.O./N.C. switching
Analog/zero shift
*
Chatter prevention
Display color
Power-save
*Press button 5 times while holding down the button to return the
sensor to its default configuration.
15
. Specifications
Sensor head
Model
Rated pressure
range
Pressure resistance
Adaptive fluids
Pressure type
Temperature
characteristics
Pressure port
Ambient temperature
Relative humidity
Vibration
Shock Resistance
Housing material
Weight
AP-41M/41
AP-43 AP-44 AP-48
0 to 0 to +101.3 to -101.3 to
-101.3 kPa 1.000 MPa -101.3 kPa +101.3 kPa
500 kPa 1.5 MPa 500 kPa 500 kPa
Air, non-corrosive gasses
Gage pressure
Differential pressure
Within ±2 % of F.S. (at 25 °C)
(in temperature range of 0 to 50 °C)
M5 male screw/
PT1/8
M3 male screw (AP-41M)
0 to +50 °C (No freezing)
35 to 85 % RH (No condensation)
10 to 55 Hz, compound amplitude 1.5 mm, 4 hours for each of XYZ axes
1,000 m/s
2
, 10 times for each of XYZ axes, total 60 times
Case: PBT; Screws: SUS303
7 g (not including cables) / 70 g (including
35 g/98 g
3-m cable) (4.8 g / 67.8 g for AP-41M)
Environmental resistance
Amplifier
Model
Head combination
Power supply voltage
Current
consumption
Display method
Configuration/display range *1
Operating status indicators
Standard mode
High-resolution mode
Repeatability
Hysteresis *2
Display temperature
characteristics
Response
(chatter
prevention feature)
Zero shift input
Analog output
Ambient temperature
Relative humidity
Vibration
Housing material
Weight
Accessories
AP-C40
AP-C40P
AP-41M/41 AP-43 AP-44 AP-48
12 to 24 VDC±10% Ripple (P-P) 10% or less
12 V operation 24 V operation
Normal 780 mW (65 mA) or less 1080 mW (45 mA) or less
Eco mode 540 mW (45 mA) or less 840 mW (35 mA) or less
3.5 digit two-color 7 segment LED (11 mm character height)
Display cycle: 10 times/second
-15 to +110 % of F.S.
Red LED x 2 (supports control output 1 / control output 2)
0.1 kPa
0.001 MPa
0.1 kPa 0.1kPa
0.01 kPa 0.1 kPa 0.02 kPa 0.02 kPa
±0.2 % of F.S.
Variable (standard 0.5% of F.S.)
±1 % of F.S. or less
Selectable from 1, 2.5, 5, 100, 500 ms
(1 ms during high-speed mode operation)
Input time 2 ms or greater (Switchable with analog output.)
NPN open collector Max. 100 mA (40 V or less)
Residual voltage 1 V or less, 2 outputs (NO/NC switchable)
PNP open collector Max. 100 mA (30 V or less)
Residual voltage 1 V or less, 2 outputs (NO/NC switchable)
1to 5 V Output impedance 1 k or less (Switchable with zero shift input.)
0 to +50 °C (No freezing)
35 to 85 % RH (No condensation)
10 to 55 Hz, compound amplitude 1.5 mm, 2 hours for each of XYZ axes
Front case: polysarfun; Rear case: PBT; Front sheet:
polycarbonate; Pressure port: die-cast zinc
Approx. 19 g (not including cables) / Approx. 74 g (including 2-m cable)
Power cord (2-m, connector type) Head connectors, units sticker
Rating
Resolution
Environmental
resistance
NPN output
PNP output
NPN output
PNP output
Control
output
16
. Error Displays and Corrective Actions
Error displays during normal operation
No difference in sensitivity
(during 2 point tuning/active
tuning).
There is an applied pressure
of ±5 % of F.S. during ambient
pressure compensation.
There is no sensor head
connected.
The connection to the sensor head
is broken.
An excess current is flowing to the
control output.
Reading is falling below
(exceeding) configuration/display
pressure range.
Reading is exceeding (falling
below) configuration/display
pressure range.
When there were not at least 2
shift inputs during active 2 point
tuning.
Adjust the air pressure device so that
there will be a difference in sensitivity.
(Return to atmospheric pressure.)
Repeat atmospheric compensation.
Verify that a sensor head is connected
and turn the power on again.
Repair the sensor head disconnection
and turn the power to the sensor back
on.
Check the load and return it to the
rated range.
Return the pressure to the rated
pressure range.
Return the pressure to the rated
pressure range.
Repeat the active tuning procedure
so that there are at least 2 shift inputs.
Display Cause Solution
* Contact KEYENCE for information about error displays other than those
described above.
*1 During focus mode operation, restricted to focus range.
*2 During focus mode operation, standard 0.1% of F.S.
(1) KEYENCE warrants the Products to be free of defects in materials and
workmanship for a period of one (1) year from the date of shipment. If any models
or samples were shown to Buyer, such models or samples were used merely to
illustrate the general type and quality of the Products and not to represent that the
Products would necessarily conform to said models or samples. Any Products
found to be defective must be shipped to KEYENCE with all shipping costs paid by
Buyer or offered to KEYENCE for inspection and examination. Upon examination
by KEYENCE, KEYENCE, at its sole option, will refund the purchase price of, or
repair or replace at no charge any Products found to be defective. This warranty
does not apply to any defects resulting from any action of Buyer, including but not
limited to improper installation, improper interfacing, improper repair, unauthorized
modification, misapplication and mishandling, such as exposure to excessive
current, heat, coldness, moisture, vibration or outdoors air. Components which
wear are not warranted.
(2) KEYENCE is pleased to offer suggestions on the use of its various Products. They
are only suggestions, and it is Buyer's responsibility to ascertain the fitness of the
Products for Buyer’s intended use. KEYENCE will not be responsible for any
damages that may result from the use of the Products.
(3) The Products and any samples ("Products/Samples") supplied to Buyer are not to
be used internally in humans, for human transportation, as safety devices or fail-
safe systems, unless their written specifications state otherwise. Should any
Products/Samples be used in such a manner or misused in any way, KEYENCE
assumes no responsibility, and additionally Buyer will indemnify KEYENCE and
hold KEYENCE harmless from any liability or damage whatsoever arising out of
any misuse of the Products/Samples.
(4)
OTHER THAN AS STATED HEREIN, THE PRODUCTS/SAMPLES ARE
PROVIDED WITH NO OTHER WARRANTIES WHATSOEVER. ALL EXPRESS,
IMPLIED, AND STATUTORY WARRANTIES, INCLUDING, WITHOUT
LIMITATION, THE WARRANTIES OF MERCHANTABILITY, FITNESS FOR A
PARTICULAR PURPOSE, AND NON-INFRINGEMENT OF PROPRIETARY
RIGHTS, ARE EXPRESSLY DISCLAIMED.
IN NO EVENT SHALL KEYENCE AND ITS AFFILIATED ENTITIES BE LIABLE
TO ANY PERSON OR ENTITY FOR ANY DIRECT, INDIRECT, INCIDENTAL,
PUNITIVE, SPECIAL OR CONSEQUENTIAL DAMAGES (INCLUDING,
WITHOUT LIMITATION, ANY DAMAGES RESULTING FROM LOSS OF USE,
BUSINESS INTERRUPTION, LOSS OF INFORMATION, LOSS OR
INACCURACY OF DATA, LOSS OF PROFITS, LOSS OF SAVINGS, THE COST
OF PROCUREMENT OF SUBSTITUTED GOODS, SERVICES OR
TECHNOLOGIES, OR FOR ANY MATTER ARISING OUT OF OR IN
CONNECTION WITH THE USE OR INABILITY TO USE THE PRODUCTS, EVEN
IF KEYENCE OR ONE OF ITS AFFILIATED ENTITIES WAS ADVISED OF A
POSSIBLE THIRD PARTY’S CLAIM FOR DAMAGES OR ANY OTHER CLAIM
AGAINST BUYER.
In some jurisdictions, some of the foregoing warranty
disclaimers or damage limitations may not apply.
BUYER'S TRANSFER OBLIGATIONS:
If the Products/Samples purchased by Buyer are to be resold or delivered
to a third party, Buyer must provide such third party with a copy of this
document, all specifications, manuals, catalogs, leaflets and written
information provided to Buyer pertaining to the Products/Samples.
E 1101-3
WARRANTIES AND DISCLAIMERS
Page view 4
1 2 3 4 5 6

Comments to this Manuals

No comments