CHARACTERISTICS (TYPICAL)
LB-041/LB-1001(W): 40 mm ± 5 mm
Shift-point adjustment range Span adjustment range
LB-081/LB-1101(W): 80 mm ± 15 mm
Shift-point adjustment range Span adjustment range
Changes in detection span when target is tilted Changes in detection span when target is tilted
The shift-point adjustment range shows the range where the output voltage reading can be shifted to zero using the SHIFT adjustment trimmer (oper-
ates when DIP switch 4 is set to LOCK). The AUTO ZERO function (operates when DIP switch 4 is set to FREE), allows 0.V resetting at any position
within the measuring range.