Keyence IL Series User Manual Page 134

  • Download
  • Add to my manuals
  • Print
  • Page
    / 140
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 133
A-8
IL-E
Appendix
2 Display Screen and Output
Normally, the judgment value (P.V.) is displayed on the main display (upper level).
This section describes the judgment output and analog output status when displays other
than numbers appear on the main display.
*1 The output state of judgment output can be set to N.O. (Normally Open) or N.C. (Normally
Close).
“5. Output State” (page 4-14)
Reference
The judgment indicator on the sensor amplifier operates in the same way as
Normally Open regardless of the output state setting.
“Setting the Tolerance Setting Value” (page 3-10)
Status
Amplifier Control input Control output
Analog
output
Upper
level
main
display
Judgment
indicator*
1
Timing
/Reset
Bank
switching/
emission
stop
Zero-shift
Judgment
output*
1
Alarm
Voltage
(current)
value
Measuring
Judgment
value
(P.V)
Measurement
results
Ye s Ye s Ye s
Measurement
results
Output:
ON
Display:
OFF
Voltage
(current) for
measured
value
Out of measurement
range
----- All off Yes Yes No All OFF
Output:
OFF
Display:
ON
Analog
voltage
output: 5.5 V
fixed
Analog
current output:
3.0 mA fixed
Out of display range
FFFF
Only HI
lights
Ye s Ye s Ye s
Only
HIGH
output ON
Output:
ON
Display:
OFF
Fixed to upper
limit of analog
output range (For
1-5 V, fixed to 1 V)
(When upper limit
< lower limit: 1 V)
Out of display range
-FFFF
Only LO
lights
Ye s Ye s Ye s
Only LOW
output ON
Output:
ON
Display:
OFF
Fixed to lower limit
of analog output
range (For 1-5 V,
fixed to 1 V)
(When upper limit
< lower limit: 5 V)
Setting
Setting
item
Follows
setting
details
During
error:
No
Other
than
error:
Ye s
Ye s
Outside
measurement
range,
mid-error,
mid-high-pass
filter: No
Follows
setting
details
Output:
ON
Display:
OFF
Follows
setting details
Other than [Erc],
[ErE] errors
"Error
Displays and
Corrective Actions"
(page 4)
Error
display
HI/LO
simulta-
neously
light
No Yes No
HIGH/
LOW
output
simulta-
neously
ON
Output:
ON
Display:
OFF
Analog voltage
output: 5.5 V
fixed
Analog current
output: 3.0 mA
fixed
Overcurrent error
ErC All off Yes Yes Yes All OFF
Measurement
in progress, or
same as out of
measurement
range
Voltage
(current) for
measured
value
EEPROM error
ErE
Measurement
results
Ye s Ye s Ye s
Measurement
results
Measurement
in progress, or
same as out of
measurement
range
Voltage
(current) for
measured
value
LASER
BANK
0
1
2
3
HI
LO
R.V.
ANALOG
HI SHIFT
ZERO SHIFT
TIMING
LO

HOLD CALC
CHECK
GO
LASER
BANK
0
1
2
3
HI
LO
R.V.
ANALOG
HI SHIFT
ZERO SHIFT
TIMING
LO
((((
HOLD CALC
CHECK
GO
LASER
BANK
0
1
2
3
HI
LO
R.V.
ANALOG
HI SHIFT
ZERO SHIFT
TIMING
LO
((((
HOLD CALC
CHECK
GO
LASER
BANK
0
1
2
3
HI
LO
R.V.
ANALOG
HI SHIFT
ZERO SHIFT
TIMING
LO
GO
HOLD CALC
CHECK
'T%
LASER
BANK
0
1
2
3
HI
LO
R.V.
ANALOG
HI SHIFT
ZERO SHIFT
TIMING
LO
GO
HOLD CALC
CHECK
'T'
Page view 133
1 ... 133 134 135 136 137 138 139 140

Comments to this Manuals

No comments