Chapter 4 Multi-Drop Link Mode Control Procedure
4
Description of setup commands
Saving settings/Initializing settings/Quitting SETUP mode
HOST MODE
To set a read error code, use the following command format.
Example: To set the read error code to “BR”
WP554252 * B = 42h, R = 52h
Function Command Response Description Error code
Saving settings SAVE OK See p. 74. 00, 02,
in the EEPROM 05, 14
Initializing DFLT OK Resets the current settings 00, 02,
settings to the default values and 05, 14,
saves them in the EEPROM. 15
Quitting SEND OK See p. 74. 00, 02,
SETUP mode 05, 14
Tips
B R
Mode
Function
Command
Response
Description
Change
WP00n
OK
n = 0: Multi-drop link
n = 1: Multi-head scan
mode
Confirm RP00 00n
Interference
suppression
Trigger
Change
WP06n
OK
n = 0: Disable
n = 1: Enable
RP06Confirm 06n
ON time in
interference
suppression
mode
Change WP47nnn
OK
nnn = 001 to 255
(Units: 10 ms)
Confirm
RP47
47nnn
Read mode
Change
WP12n
OK
n = 0: Single
n = 1: Multi-label 1
n = 2: Multi-label 2
Confirm RP12 12n
Data trans-
mission timing
(Effective in
signal label
mode only)
Change
WP13n OK
n = 0: After read
n = 1: At trigger
Confirm RP13
13n
Read error
code
Change
WP55hhh..
OK
hhh... = Read error code
(up to eight characters)
* To set a read error code,
use HEX (hexadecimal)
codes.
* hhh... = FF: Read error
code is not set.
Confirm RP55
55hhh..
Error code
00, 02,
05, 07,
14
00, 02,
05, 07,
09, 14
00, 02,
05, 08,
14
00, 02,
05, 07,
14
00, 02,
05, 10,
12, 14