Chapter 4 Multi-Drop Link Mode Control Procedure
82
4
RS-485 SETUP
Baud rate
Function
Command
Response
Description
Change
WP75n OK
n = 5: 38400 bps
n = 6: 31250 bps
n = 7: 19200 bps
n = 0: 9600 bps
n = 1: 4800 bps
n = 2: 2400 bps
n = 3: 1200 bps
n = 4: 600 bps
Confirm
RP75
75n
Data length
Change
WP70n
OK
n = 0: 7 bits
n = 1: 8 bits
Confirm
RP70
70n
Parity Change
WP71n OK
n = 0: None
n = 1: Set parity
Confirm RP71
71n
Parity type
Change WP72n
OK n = 0: Even
n = 1: Odd
Confirm RP72 72n
Stop bit length
WP73nChange OK
n = 0: 1 bit
n = 1: 2 bits
Confirm
RP73 73n
Error code
* To set the parity type,
use the "Parity type"
command.
00, 02,
05, 08,
14
00, 02,
05, 07,
14