Chapter 4 Multi-Drop Link Mode Control Procedure
4
ID SETUP
RS-232C SETUP
Baud rate
Function
Command
Response
Change
WP35n OK
n = 5: 38400 bps
n = 6: 31250 bps
n = 7: 19200 bps
n = 0: 9600 bps
n = 1: 4800 bps
n = 2: 2400 bps
n = 3: 1200 bps
n = 4: 600 bps
Confirm
RP35
35n
Data length
Change
WP30n
OK
n = 0: 7 bits
n = 1: 8 bits
Confirm
RP30
30n
Parity Change
WP31n OK
n = 0: None
n = 1: Set parity
Confirm RP31
31n
Parity type
Change WP32n
OK n = 0: Even
n = 1: Odd
Confirm RP32 32n
Stop bit length
WP33nChange OK
n = 0: 1 bit
n = 1: 2 bits
Confirm
RP33 33n
RTS/CTS
control
Change WP22n OK n = 0: Disable
n = 1: Enable
Confirm RP322 22n
Registering ID
number (for
each unit)
Function
Command
Response
Description
Change
WIDmmn
mm = 01 to 31 (ID 3
number)
n = 0: Do not register
n = 1: Register
mmn
Registering
serial numbers
(Register all ID
numbers more
than the
specified
number.)
Confirm
RIDmm
OK
Change
WIDMAXmm
OK
mm = 01 to 31 (ID 4
number)
* If “mm” is “99” in the
response, serial ID
numbers are not
registered.
Confirm
RWIDMAXmm
MAXmm
Registering all
serial numbers
Change
WIDAnnn...n OK
n = 0: Do not register
n = 1: Register
* “n” corresponds to ID
numbers (1 to 31) in
ascending order.
Confirm
RIDA
Annn...n
00, 01,
02, 05,
07, 14
00, 01,
02, 05,
14
00, 02,
05, 07,
14
Error code
Error code
00, 02,
05, 08,
14
Description
* To set the parity type,
use the "Parity type"
command.
00, 02,
05, 07,
14
Page view 88