7-2 Device Assignments
Device assignments for multi-drop link mode and multi-head mode are different. This section
explains those differences.
Device Assignments for Multi-drop Link Mode
The data range controlled by the N-410 includes the PLC internal memory.
Set the device header address in the N-410 "PLC settings" for automatic assignment.
(Header address area or read trigger area for each ID number)
(DM header address) +00, +01 are the buffer overflow and clear areas for the connected BL Series
or SR Series device .
(DM header address) +02 to +32 is the area for specifying which address to write data read from a
code to.
(DM header address) +33 to +61 is used for sending trigger signals to connected BL Series or SR
Series devices. However, this area cannot be assigned if the "Trigger area input" of the N-410 settings
is disabled. These are available for other uses.
The write header addresses for +02 to +32 can all be set to the same address. If this is done, all BL
Series devices will write to the same address.
Address Contents
+00 ERROR
+01 ERROR Clear
+02 Data write header address for ID no. 1 (A)
+03 Data write header address for ID no. 2 (B)
+04 Data write header address for ID no. 3
::
+32 Data write header address for ID no. 31
+33 Read trigger area for ID no. 1
+34 Read trigger area for ID no. 2
+35 Read trigger area for ID no. 3
::
+63 Read trigger area for ID no. 31