Page view 91
5-8
Controlling Multi-head Mode
5
5-2 Operating in Multi-head Mode
Data Transmission Timing
Select one of the following triggers to send data to the host computer.
After read
Data is sent immediately after it has been read.
After trigger OFF
This sends data when the trigger signal coming into the N-410 is turned off (This occurs after a
set time after measurement if one-shot synchronization has been used).
Trigger input
<When data was read> <When data was not read>
*Read error
Communication
output
Read
Trigger input
<When data was read> <When data was not read>
*Read error
Communication
output
Read