4.3 Command Communication
54
Setting Bar Code Type and Number of Readable Digits for Codes 1 to 4
The following describes the parameter setting commands for Codes 1 to 4.
Be sure to send Bar code type setting command first before setting other param-
eters.
When Bar code type setting command is newly sent, all other parameters for the
specified code will return to the default settings.
In this case, set all other parameters again.
Setting change commands and setting confirmation commands are described on
the following pages.
Note
Function command being sent
Respons
e
Description
Error
Code
Setting bar code type for
codes 1 to 4.
Change CODEm=n OK m= 0 to 3:Codes 1 to 4
n= 0:CODE 39
1:ITF
2:Industrial2-of-5
3: Codabar
4: UPC/EAN
5: CODE128
6: COOP2-of-5
7: None
00, 01
03, 05
08, 14
Confirm CODEm mn
Setting Max. No. of readable
digits
Change MAXm=nn OK m= 0 to 3: Codes 1 to 4
nn= 01 to 32
* For CODE39, Codabar: 03 to 32
* For ITF: 02 to 32
* For CODE128: 01 to 64
Note:
With EAN code, this command causes error.
00, 01
03, 04
05, 09
14
Confirm MAXm mnn
Setting Min. No. of readable
digits
Change MINm=nn OK
Confirm MINm mnn
Sending start/stop character.
Change WCm00n OK m= 0 to 3: Codes 1 to 4
n= 0: Disable
1: Enable
00, 02
03, 04
05, 07
14
Confirm RCm00 00n
Inspection of check digit
(Modulus 43)
Change WCm01n OK
m= 0 to 3: Codes 1 to 4
n= 0: Disable
1: Enable
Confirm RCm01 01n
Function Command being sent
Respons
e
Description
Error
Code
Sending check digit.
Change WCm02n OK m= 0 to 3: Codes 1 to 4
n= 0: Disable
1: Enable
00, 02
03, 04
05, 07
14
Confirm RCm02 02n
Inspection of check digit
(Modulus 10)
Change WCm10n OK
m= 0 to 3: Codes 1 to 4
n= 0: Disable
1: Enable
Confirm WCm10 10n
Sending check digit.
Change WCm11n OK m= 0 to 3: Codes 1 to 4
n= 0: Disable
1: Enable
Confirm RCm11 11n
Sending start/stop character.
Change WCm30n OK m= 0 to 3: Codes 1 to 4
n= 0: Disable
1: Enable
Confirm RCm30 30n
Start/Stop character type
Change WCm31n OK m= 0 to 3: Codes 1 to 4
n= 0: Lower case
1: Upper case
Confirm RCm31 31n
Inspection of check digit
Change WCm32n OK m= 0 to 3: Codes 1 to 4
n= 0: Disable
1: Enable
Confirm RCm32 32n
Sending check digit
Change WCm33n OK m= 0 to 3: Codes 1 to 4
n= 0: Disable
1: Enable
Confirm RCm33 33n
CODE39
CODE39
CODE39
ITF
ITF
Codabar
Codabar
Codabar
Codabar