A.1 Specifications
62
A.1 Specifications
BL-180/185
The internal settings of the BL-180 series are stored in the EEPROM. (Rewritable
up to 10,000 times)
Model
BL-180 BL-185
Model (with connector) BL-180SO(7030) BL-185SO(7031)
Scanning direction
Front Side
Light source/Light receiving element
LED/CCD image sensor
Scanning distance
33 mm ± 10 mm
1
(Using narrow bars of at least 0.19
mm in width)
Readable bar width
0.125 to 1.0 mm
2
Maximum label width
80 mm
3
(Using narrow bars of at least 0.19 mm in
width)
PCS
0.45 or more (Reflectance of white part: 75% or more)
Scanning rate
500 scans/sec
Target code
CODE39, ITF, Industrial2-of-5, COOP2-of-5, Codabar,
CODE128, EAN/UPC(A-E)
No. of readable digits
32 digits
Trigger input
Non-voltage input (contact or solid-state) TTL input is
also possible.
Rated load
24 VDC, 100 mA
Ambient light
Sunlight, Incandescent lamp: 10,000 lux,
Fluorescent lanp: 3,000 lux.
Current consumption
300 mA max.
Weight
Approx. 165 g Approx. 180 g
1. 33
±
5 mm when the narrowest bar is less than 0.19 mm.
2. Readable bar width indicates the range of the narrowest readable bar.
3. 60 mm when the narrowest bar is less than 0.19 mm.
OK/NG output
Output type
NPN open collector output
Leakage current (at off)
0.1 mA max.
Residual voltage (at on)
0.5 V max.
Ambient temperature
0 to 40°C
Relative humidity
35 to 85%
Vibration
10 to 55 Hz, Double amplitude in X, Y and Z directions, 2 hours
respectively
Power supply voltage
5 VDC±5%
1
Serial interface
Applied standard
EIA RS-232C port
Synchronization
Start-stop
Transmission code
ASCII
Baud rate
600 to 38,400 bps
Data length
7 bits/8 bits
Parity check
None/even/odd
Stop bit
1/2 bit
1. Use a stable power supply of 5 VDC
±