Keyence DL-PN1 User Manual Page 12

  • Download
  • Add to my manuals
  • Print
  • Page
    / 36
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 11
10
- PROFINET Communication Unit DL-PN1 User's Manual (IB) -
Record Data Communication
What is record data communication?
Record data communication is a function that performs communication by issuing
commands when desired. It is used for applications which do not require the punctuality
of data I/O communication, such as reading and writing I/O device settings.
Basic Format and Flow of Record Data Communication
Record data communication uses function block, which blocks circuits being used in a
program. For Siemens SIMATEC Manager / TIA Portal, use SFB52"RD REC" and
SFB53"WR REC".
(1) Record data
communication command
(3) Record data
communication response
I/O controller Sensor amplifier
Send
Receive
Receive
Send
(2) Interpret and
execute command
DL-PN1
SFB52"RD REC"
Reads data.
SFB53"WR REC"
Writes data.
Parameter name Description
EN Enables.
EN0 Shows that EN is enabled.
REQ Enables when making a request.
ID Enters the DL-PN1 or sensor amplifier ID number.
INDEX Enters the Access Address Index number.
MLEN Set to 4.
6)%
5HDGD3URFHVV'DWD5HFRUG
(1 5'5(& (1
5(4 9$/,'
,' %86<
,1'(; (5525
0/(1 67$786
5(&25' /(1
6)%
:ULWHD3URFHVV'DWD5HFRUG
(1
:55(&
(1
5(4 9$/,'
,' %86<
,1'(; (5525
0/(1 67$786
5(&25'