- PROFINET Communication Unit DL-PN1 User's Manual (IB) -
130 Measurement mode DINT R/W 0
0: Percent mode
1: Dimension mode
131 Received/Blocked light mode DINT R/W 0
0: Received light mode
1: Blocked light mode
132 Reserved for system
133 Averaging/High-pass filter DINT R/W 5
Averaging
0: 1 time
1: 2 times
2: 4 times
3: 8 times
4: 16 times
5: 64 times
6: 256 times
7: 1024 times
8: 4096 times
9: 16384 times
High-pass filter
10: 0.1Hz
11: 0.2Hz
12: 0.5Hz
13: 1Hz
14: 2Hz
15: 5Hz
16: 10Hz
17: 20Hz
18: 50Hz
19: 100Hz
134 Output mode DINT R/W 0
0: N.O (Normal open)
1: N.C (Normal close)
135 Reserved for system
136 Hold function setting DINT R/W 0
0: Sample hold
1: Peak hold
2: Bottom hold
3: Peak-to-peak hold
4: Auto peak hold
5: Auto bottom hold
137 Auto hold trigger level *7 DINT R/W +90.00 -999.99 to +999.99
138 Timing input setting DINT R/W 0
0: Level
1: Edge
139 Delay Timer DINT R/W 0
0: OFF
1: On delay
2: Off delay
3: One-shot
140 Timer duration DINT R/W 60 1 to 9999
141 Hysteresis DINT R/W 0.00 0.00 to 999.99
142 Analog output scaling
*17
*19
DINT R/W 0
0: Initial state
1: Free range
143 Analog output upper limit
*7
*17
*19
DINT R/W +100.00 -999.99 to +999.99
144 Analog output lower limit
*7
*17
*19
DINT R/W 0 -999.99 to +999.99
145 External input setting *18 DINT R/W 0
0: Default
1: User setting
Index
(DEC)
Function name
Description
Data
type
Attribute
Default
value
Value
Page view 19