Page view 14
13
- PROFINET Communication Unit DL-PN1 User's Manual (IB) -
96
1st Sensor Head 1
Identification
Stores the type of the slot
number 01 sensor head (light
transmitter).
4byte
DINT
R
0: Sensor head is not
connected, or light
receiver is connected.
1: Light transmitter of IB-01
2: Light transmitter of IB-05
3: Light transmitter of IB-10
4: Light transmitter of IB-30
:: : ::
99
4th Sensor Head 1
Identification
Stores the type of the slot
number 04 sensor head (light
transmitter).
4byte
DINT
R
0: Sensor head is not
connected, or light
transmitter is connected.
1: Light receiver of IB-01
2: Light receiver of IB-05
3: Light receiver of IB-10
4: Light receiver of IB-30
100 to
111
Reserved for system
112
1st Sensor Head 2
Identification
Stores the type of the slot number
01 sensor head (light receiver).
4byte
DINT
R
:: : ::
115
4th Sensor Head 2
Identification
Stores the type of the slot number
04 sensor head (light receiver).
4byte
DINT
R
116 to
127
Reserved for system
128 Product code 1
Stores the product code of
the slot number 01 sensor
amplifier.
2byte
WORD
R
:: : ::
131 Product code 4
Stores the product code of
the slot number 04 sensor
amplifier.
2byte
WORD
R
132 to
143
Reserved for system
144 Revision 1
Stores the revision of the slot
number 01 sensor amplifier.
2byte
WORD
R 0101H to FFFFH
:: : :: :
147 Revision 4
Stores the revision of the slot
number 04 sensor amplifier.
2byte
WORD
R 0101H to FFFFH
148 to
159
Reserved for system
160
Comparator value 0 (Slot
Number 1)
Used when reading the
comparator value (P.V. value)
of slot number 01.
*2
4byte
DINT
R
In percent mode:
-999.99 to +999.99
In size mode:
-99.999 to +99.999
:: : ::
163
Comparator value 0 (Slot
Number 4)
Used when reading the
comparator value (P.V. value)
of slot number 04.
*2
4byte
DINT
R
164 to
175
Reserved for system
176
Number of decimal places
(Current value 0, Slot
Number 1)
Used when reading the
decimal position of the slot
number 01 comparator value
(P.V. value).
4byte
DINT
R
:: : ::
179
Number of decimal places
(Current value 0, Slot
Number 4)
Used when reading the
decimal position of the slot
number 04 comparator value
(P.V. value).
4byte
DINT
R
Index
(DEC)
Function name Description
Data
type
Attribute
Value
Page view 14
1 2 ... 10 11 12 13 14 15 16 17 18 19 20 ... 35 36

Comments to this Manuals

No comments