3-3 Communication Methods
3-21
3
Communicating with the SK-1000 Series
- CC-Link Compatible Network Unit DL-CL1 User’s Manual (SK-1000) -
This example changes the BANK number associated with ID01 and ID02.
(1) Specify a new BANK number in "select BANK number" and execute "request to change BANK" (0 ->
1). In this example, the BANK is changed for both ID01 and ID02 simultaneously.
(2) The "BANK change complete" signal flips from 0 to 1 when the change to the specified BANK
number is completed.
(3) When the "request to change BANK" command is set to 0, the "BANK change complete" parameter
flips to 0.
(4) If an error occurs while changing the BANK for a sensor amplifier of any ID number, the "BANK
change error" signal flips from 0 to 1 (the output is the logical disjunction (OR) for IDs 01 to 04).
Check the value specified in the "select BANK number" parameter.
(5) To clear the BANK change error, set the "clear BANK change error" parameter to 1.
Set the BANK change method to "button."
Changing the BANK Number of Sensor Amplifiers
PLC
Sensor amplifier
Select BANK number 1 (BANK 1) 3 (BANK 3)
RWw04
Request to change BANK of ID 01
RY60
Request to change BANK of ID 02
RY61
Completed in changing BANK of ID 01
RX60
Completed in changing BANK of ID 02
RX61
(4)
BANK change error
RX6F
(5)
Clear BANK change error
RY6F
BANK number of ID 01 1 (BANK 1)
BANK number of ID 02 1 (BANK 1) 3 (BANK 3)
1
1
1
1
1
1
0
0
0
0
0
0
(3)
(1)
(2)
Point