3-4 Command Parameter List
3-27
3
Communicating with the SK-1000 Series
- CC-Link Compatible Network Unit DL-CL1 User’s Manual (SK-1000) -
*1 Bit assignment for ID numbers
*2 Bit assignment for outputs
03
0101 Output ID 01
Output state of ID 01.
Each output is assigned to
the corresponding bit.*2
Same content as remote
input RX.
R
WORD 0
For each bit
0: Output OFF
1: Output ON
... ...
0108 Output ID 08
Output state of ID 08.
Each output is assigned to
the corresponding bit.*2
Same content as remote
input RX.
0201
Current value ID
01
Reads the current value of
ID 01.
Same content as the
current value in remote
register RWr.
INT32 0... ...
0208
Current value ID
08
Reads the current value of
ID 08.
Same content as the
current value in remote
register RWr.
0301
Decimal point
information for
current value ID 01
Reads the decimal point
position of ID 01.
UINT
0: No decimal point
1: One decimal
2: Two decimals
3: Three decimals
4: Four decimals
... ...
0308
Decimal point
information for
current value ID 08
Reads the decimal point
position of ID 08.
05
0000
Number of
connectable
units
Reads the number of
connected sensor
amplifiers.
R UINT 0 1 to 08
0101
Product code of
ID 01
Reads the product codes of
sensor amplifiers of
respective ID numbers.
R UINT
0
4024: Main unit
4025: Expansion
unit
... ...
0108
Product code of
ID 08
0201 Head code ID 01
Not used with the SK-1000
series.
0 -... ...
0208 Head code ID 08
10
**00
to**FF
Commands in this data category are the same as those in data category 00. When such a
command is used to read a parameter with decimal point information from a sensor amplifier, the
command can retrieve the decimal point position information.
The differences from data category 00 are as follows:
The data category specified in the command is changed from 00h o 10h. The others of the
command format are the same as in data category 00.
The decimal point position information is retrieved as a command response. For details of
communication responses, see "Command response list" (page 3-10).
Data
category
(HEX)
Data
number
(HEX)
Name Description
Attribute
Data
type
Default
value
Parameter range
DL ID15 ID14 ID02 ID01
bit 15 bit 14 bit 13 bit 1 bit 0
Unusable (Not used) Alarm outputGOLOHI
bit 15 bit 4 bit 3 bit 2 bit 1 bit 0
Page view 54