Keyence DL-PN1 User Manual Page 29

  • Download
  • Add to my manuals
  • Print
  • Page
    / 36
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 28
27
- PROFINET Communication Unit DL-PN1 User's Manual (IB) -
Troubleshooting
The indicator LEDs on the DL-PN1 can be used to determine the causes of errors.
Link/activity indicator (LINK/ACT)
This indicator indicates whether the DL-PN1 is communicating correctly.
System Failure indicator (SF)
This indicator indicates whether the DL-PN1 is operating normally.
Link/activity indicator (Green)
System Failure indicator (Orange, Red)
Bus Failure indicator (Red)
Sensor communication indicator (Green, Red)
LED Status Condition Corrective Action
Green
Solid The DL-PN1 is normally linked. -
Flashing
The DL-PN1 is normally linked and is
now exchanging data.
-
Not lit
Power is not supplied to the DL-PN1.
The DL-PN1 is not linked.
Check if the power supply is correctly connected.
Check if the DL-PN1 is correctly connected to the
sensor amplifier.
Check if the IP address is correct.
Check if the power supply of the connected device
or Ethernet switch is correctly connected.
Check if the cable is correctly connected.
LED Status Condition Corrective Action
Solid red
There may be a system error on the
DL-PN1 or a connected sensor.
Check the D-bus LED status.
Check if the number of connected sensor
amplifiers exceeds the maximum number of
connectable units.
Check if the IP address is correct.
Check if the slot number is correct.
Check if the DL-PN1 is correctly connected to the
sensor amplifier.
Check if there is an electrical noise source near the
DL-PN1.
Flashing orange
Flash LED was requested on the I/O
controller.
Flashes approximately 4 times per
second.
-
Not lit The DL-PN1 is normally operating. -