427GBPROFINET Communication UnitDL-PN1 (IB)User's Manual Read this manual before use.Keep this manual in a safe place for future reference.
8- PROFINET Communication Unit DL-PN1 User's Manual (IB) -Reading an output from a sensor amplifierAvailable outputs: High, Low, GoThis example
9- PROFINET Communication Unit DL-PN1 User's Manual (IB) -Reading comparator values (P.V. values) from sensor amplifiersThis example shows how to
10- PROFINET Communication Unit DL-PN1 User's Manual (IB) -Record Data Communication What is record data communication?Record data communicati
11- PROFINET Communication Unit DL-PN1 User's Manual (IB) -PointTo input the ID number for the DL-PN1 into ID, refer to the instruction manual fo
12- PROFINET Communication Unit DL-PN1 User's Manual (IB) -64 Error stateWhen the sensor amplifier is in the error state, the corresponding bit
13- PROFINET Communication Unit DL-PN1 User's Manual (IB) -961st Sensor Head 1 IdentificationStores the type of the slot number 01 sensor head (l
14- PROFINET Communication Unit DL-PN1 User's Manual (IB) -*1 Functions assigned to the external input request 1 to 4 are as follows:• External
15- PROFINET Communication Unit DL-PN1 User's Manual (IB) -10Reference light registration requestDINT C11 Adjust request DINT C12 Adjust reset re
16- PROFINET Communication Unit DL-PN1 User's Manual (IB) -39Peak-hold value in hold mode*4*5*7DINT R -999.99 to +999.9940Bottom-hold value in
17- PROFINET Communication Unit DL-PN1 User's Manual (IB) -64 Group2 Entry count DINT R 1265 HIGH setting value (BANK 0) *7 DINT R/W +20.00 -999.
IntroductionThis manual describes the basic operations and hardware functions of the DL-PN1.Read the manual carefully to ensure safe performance and f
18- PROFINET Communication Unit DL-PN1 User's Manual (IB) -130 Measurement mode DINT R/W 00: Percent mode1: Dimension mode131 Received/Blocked
19- PROFINET Communication Unit DL-PN1 User's Manual (IB) -146External input 1 function selection*18 DINT R/W 00: Zero shift input1: Bank A input
20- PROFINET Communication Unit DL-PN1 User's Manual (IB) -*1 The error content of the sensor amplifier can be checked by noting the ON/OFF sta
21- PROFINET Communication Unit DL-PN1 User's Manual (IB) -*3 If the judgment value is correct, the parameter range isfrom - 999.97 to +999.98 (p
22- PROFINET Communication Unit DL-PN1 User's Manual (IB) -*10 The result of the "initial reset request" motion command is included i
23- PROFINET Communication Unit DL-PN1 User's Manual (IB) -*13 This command reads the execution result of the "tolerance tuning request"
- PROFINET Communication Unit DL-PN1 User's Manual (IB) -24AppendixSpecificationsThe specifications of the DL-PN1 are as follows:Product name PRO
25- PROFINET Communication Unit DL-PN1 User's Manual (IB) -Dimensions25.635.443.594.538.1(42.5 )29.4(Unit : mm)
26- PROFINET Communication Unit DL-PN1 User's Manual (IB) -Data Processing TimeThe data update time for data I/O communication is shown below.
27- PROFINET Communication Unit DL-PN1 User's Manual (IB) -TroubleshootingThe indicator LEDs on the DL-PN1 can be used to determine the causes of
1Overview of PROFINETWhat is PROFINET?PROFINET is an open industrial networking standard developed and maintained by the PI (PROFINET International).
28- PROFINET Communication Unit DL-PN1 User's Manual (IB) - Bus Failure indicator (BF)This indicator indicates whether the DL-PN1 is communica
29- PROFINET Communication Unit DL-PN1 User's Manual (IB) -Types of error and error code Error code listThe following error codes may occur in t
30- PROFINET Communication Unit DL-PN1 User's Manual (IB) -Reference programsThis section introduces reference programs for carrying out PROFIN
31- PROFINET Communication Unit DL-PN1 User's Manual (IB) -Rewrite the HI setting value Explanation of the program Network1M6.0 (Address 6, Bit
32- PROFINET Communication Unit DL-PN1 User's Manual (IB) - Network3If the READ command send processing is successful, M9.1 (Address 9, Bit 1)
WARRANTIES AND DISCLAIMERS(1) KEYENCE warrants the Products to be free of defects in materials and workmanship for a period of one (1) year from the d
Copyright (c) 2014 KEYENCE CORPORATION. All rights reserved.427GB 1104-1 427GB Printed in Japan
2- PROFINET Communication Unit DL-PN1 User's Manual (IB) -Specifying the IP address using the DCP protocolIn the PROFINET communication, you ca
3- PROFINET Communication Unit DL-PN1 User's Manual (IB) -Communicating with the IB SeriesTypes and Number of Connectable Sensor AmplifiersThe DL
4- PROFINET Communication Unit DL-PN1 User's Manual (IB) -DL-PN1 PROFINET Communication OverviewThe DL-PN1 enables you to read or write various
5- PROFINET Communication Unit DL-PN1 User's Manual (IB) - Data I/O communication device map (DL-PN1 PROFINET I/O controller) DL-PN1 (Slot 0)
6- PROFINET Communication Unit DL-PN1 User's Manual (IB) -* "a" represents a Slot number. When Addresses were assigned in order, the
7- PROFINET Communication Unit DL-PN1 User's Manual (IB) -*1 External input request to the sensor amplifiers connected to the DL-PN1 (Slot 0) can
Comments to this Manuals