3-2 Device Maps
3-5
3
Communicating with the FD-MH series
- CC-Link Compatible Network Unit DL-CL1 User’s Manual (FD-MH) -
Number [n] denotes the first relay number assigned to the DL-CL1.
*1 See "Reading an Output from a Sensor Amplifier" (page 3-17).
*2 See "Reading Current Values (Instantaneous Flow Rate) from Sensor Amplifiers" (page 3-18).
*3 See "Reading/Writing Settings or Status of a Sensor Amplifier" (page 3-21).
See "Issuing a Motion Command to a Sensor Amplifier" (page 3-20).
Remote Output RY (Master Station -> DL-CL1)
Operating
mode
Device
no. (HEX)
Name
Communication
method
Description Reading range
Monitor mode 1
RX[n] + 53
Current Value
Update Locked
-
This is output when current value update is
locked (current value update lock request (RY[n]
+ 53) is enabled).
0: Update enabled
1: Update locked
RX[n] + 54
to 5D
System
reserved
- Unusable
RX[n] + 5E
Current value
page change
complete
*2
Used for reading the current value.This is
output when the current value page has been
changed.
0->1: Change
complete
RX[n] + 5F
Current value
page change
error
*2
Used for reading the current value.This is output
if an error occurs while changing the current
value page.
0:No Error
1:Error
RX[n] + 60
to 69
(Not used) - - -
RX[n] + 6F (Not used) - - -
RX[n] + 1B
Remote ready -
This is output when the DL-CL1 is correctly
connected to the CC-Link system.
1: Proper communication is provided.Data from
the sensor amplifi er will be updated.
0: Proper communication is not provided.Data
from the sensor amplifi er will not be updated.
0: In preparation
1: Ready
RX[n] + 3B
RX[n] + 7B
Operating
mode
Device no.
(HEX)
Name
Communication
method
Description
Writing
range
Small-memory mode 1
Small-memory mode 2
Monitor mode 1
RY[n] + 00
to 09
Integration reset input
ID 01 to ID 10
*1
Receives integration reset input by assigning
each sensor amplifi er (ID 01 to ID 10) to each RY.
0: OFF
1: ON
RY[n] + 0F System reserved - Unusable
RY[n] + 10
to 19
Flow rate hold reset
input
ID 01 to ID 10
*1
Receives fl ow rate hold reset input by assigning
each sensor amplifi er (ID 01 to ID 10) to each RY.
0: OFF
1: ON
RY[n] + 1F System reserved - Unusable
RY[n] + 20
to 29
(Not used) - -
RX[n] + 2F System reserved - Unusable
RY[n] + 30
to 39
Temperature hold
reset input
ID 01 to ID 10
*1
Receives temperature hold reset input by
assigning each sensor amplifi er (ID 01 to ID 10)
to each RY.
0: OFF
1: ON
RX[n] + 3F System reserved - Unusable