Keyence DL-CL1 User Manual Page 43

  • Download
  • Add to my manuals
  • Print
  • Page
    / 72
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 42
3-2 Device Maps
3-15
3
Communicating with the FD-MH series
- CC-Link Compatible Network Unit DL-CL1 User’s Manual (FD-MH) -
Number [n] denotes the first data memory number assigned to the DL-CL1.
*1 See "Entering an External Input into a Sensor Amplifier" (page 3-17).
*2 See "Reading/Writing Settings or Status of a Sensor Amplifier" (page 3-21).
See "Issuing a Motion Command to a Sensor Amplifier" (page 3-20).
*3 See "Reading Current Values (Instantaneous Flow Rate) from Sensor Amplifiers" (page 3-18).
*4 See "Error information list" (page 3-7).
*5 See "Command response list" (page 3-8).
Operating
mode
Device no. (HEX) Name
Communication
method
Description
Reading
range
Monitor mode 2
Full mode 1
Full mode 2
RWr[n] +12 to 13
(INT32)
Current Value
ID 04
*3
Used for reading the instantaneous fl ow rate
value.
Outputs the instantaneous fl ow rate value of the
sensor amplifi er (ID 04).
INT32
(LITTLE)
RWr[n] +14 to 15
(INT32)
Current Value
ID 05
*3
Used for reading the instantaneous fl ow rate
value.
Outputs the instantaneous fl ow rate value of the
sensor amplifi er (ID 05).
INT32
(LITTLE)
RWr[n] +16 to 17
(INT32)
Current Value
ID 06
*3
Used for reading the instantaneous fl ow rate
value.
Outputs the instantaneous fl ow rate value of the
sensor amplifi er (ID 06).
INT32
(LITTLE)
RWr[n] +18 to 19
(INT32)
Current Value
ID 07
*3
Used for reading the instantaneous fl ow rate
value.
Outputs the instantaneous fl ow rate value of the
sensor amplifi er (ID 07).
INT32
(LITTLE)
RWr[n] + 1A to 1B
(INT32)
Current Value
ID 08
*3
Used f
or reading the instantaneous fl
ow rate
value.
Outputs the instantaneous fl ow rate value of the
sensor amplifi er (ID 08).
INT32
(LITTLE)
RWr[n] + 1C to 1D
(INT32)
Current Value
ID 09
*3
Used for reading the instantaneous fl ow rate
value.
Outputs the instantaneous fl ow rate value of the
sensor amplifi er (ID 09).
INT32
(LITTLE)
RWr[n] +1E to 1F
(INT32)
Current Value
ID 10
*3
Used for reading the instantaneous fl ow rate
value.
Outputs the instantaneous fl ow rate value of the
sensor amplifi er (ID 10).
INT32
(LITTLE)
RWr[n] +20 to 21
(INT32)
(Not used) - - -
RWr[n] +22 to 23
(INT32)
(Not used) - - -
RWr[n] +24 to 25
(INT32)
(Not used) - - -
RWr[n] +26 to 27
(INT32)
(Not used) - - -
RWr[n] +28 to 29
(INT32)
(Not used)
- - -
R
Wr[n] + 2A to 3F
System
reserved
- Unusable -