Page view 35
3-2 Device Maps
3-8
- CC-Link Compatible Network Unit DL-CL1 User’s Manual (FD-MH) -
Communicating with the FD-MH series
3
* "nn" denotes the ID number in hexadecimal of sensor amplifier. (Example: 01h for ID01, ..., 0Ah for
ID10)
If there are multiple errors, the smallest error code is stored in the remote register.
Command response list
0004 Mixed connection error
A foreign sensor amplifier (i.e.,
one that cannot be intermixed)
is connected.
Remove the foreign sensor
amplifier.
0006 Number-of-units error
More sensor amplifiers are
connected than are permitted.
Observe the number of
connectable sensor amplifiers.
0007
Sensor-to-sensor
communication error
An error exists in the
communication between
sensor amplifiers.
Check the connections of the
sensor amplifiers, and then turn
off the power and back on.
nn01
Error 1 for sensor amplifier
of ID number nn
Head error (ErS)
Refer to the FD-MH series
instruction manual.
nn02
Error 2 for sensor amplifier
of ID number nn
Head connection error (ErH)
nn03
Error 3 for sensor amplifier
of ID number nn
Overcurrent error (ErC)
nn04
Error 4 for sensor amplifier
of ID number nn
EEPROM error (ErE)
nn05
Error 5 for sensor amplifier
of ID number nn
(Not used)
nn06
Error 6 for sensor amplifier
of ID number nn
nn07
Error 7 for sensor amplifier
of ID number nn
Backflow error (rEv)
nn08
Error 8 for sensor amplifier
of ID number nn
(Not used)
nn09
Error 9 for sensor amplifier
of ID number nn
Temperature lower limit error
nn0A
Error 10 for sensor amplifier
of ID number nn
Temperature upper limit error
nn0B
Error 11 for sensor amplifier
of ID number nn
Temperature sensor connection
error
(Err tEMP)
Error Information
(HEX)
*
Description Cause Corrective action
Response
(HEX)
Name Description
0000 Successfully completed. The command has been processed successfully.
0001 Command number error The command number is out of range.
0002 Data category error The data category value is out of range.
0003 ID number out of range The ID number of sensor amplifier is out of range.
0004 Data number out of range The data number is out of range.
0007 Sensor-to-sensor communication error An error exists in the communication between sensors.
0008 Motion command access error Cannot read/write to motion command data numbers.
0009
Motion command data number ou t of
range
The data number of motion command is out of range.
000A Motion command execution error Failed to execute the motion command.
000B Read inhibit Write-only data number. Cannot be read.
000C Operating status error
Command communication (reading) is temporarily
prohibited because of the operating status of the
sensor amplifier.
Page view 35