- IV Series Users Manual (Field Network) -
Data allocation in the cyclic communication
Input Assembly Address 52 to 71: Position correction information
The Bits at Address 52 to 71 of the Input Assembly have the following functions:
Address
Data
type*
Item Content Data content
52 to 53 UINT
Position correction tool
matching rate
Stores the matching rate of the
position correction tool.
0 to 100
54 to 55 UINT
Position correction tool
matching rate MAX
Stores the maximum matching
rate value of the position
correction tool.
0 to 100
56 to 57 UINT
Position correction tool
matching rate MIN
Stores the minimum matching
rate value of the position
correction tool.
0 to 100
58 to 59 UINT
Position correction tool
threshold
Stores the threshold value of the
position correction tool.
0 to 100
60 to 71 --- Reserved by system --- ---
* UINT : Unsigned 16-bit integer
UDINT : Unsigned 32-bit integer
Maximum and minimum matching rate values of the position correction tool will be reset in the same
manner as the statistics information.
If the position correction tool is not set, the data content will be “0”.
Input Assembly Address 72 to 391: Tool information
The Bits at Address 72 to 391 of the Input Assembly have the following functions:
Address
Data
type*
Item Content Data content
72 to 73 UINT Tool 1 matching rate
Stores the matching rate of Tool
1.
0 to 999
74 to 75 UINT
Tool 1 matching rate MAX
Stores the maximum matching
rate value of Tool 1.
0 to 999
76 to 77 UINT Tool 1 matching rate MIN
Stores the minimum matching
rate value of Tool 1.
0 to 999
78 to 79 UINT Tool 1 lower limit value
Stores the lower threshold value
of Tool 1.
0 to 999
80 to 81 UINT Tool 1 upper limit value
Stores the upper threshold
value of Tool 1.
0 to 999
82 to 91 --- Reserved by system --- ---
Thereafter, the information of tool 2, 3, ... 16 will be assigned for each 20-byte Address of Input Assembly.
* UINT : Unsigned 16-bit integer
UDINT : Unsigned 32-bit integer
Maximum and minimum matching rate values of the tool will be reset in the same manner as the
statistics information.
If the tool is not set, the data content will be “0”.
If the upper threshold value of the tool is not set, the data content of the tool’s upper limit value will be
“65535”.