Keyence IV Series User Manual Page 94

  • Download
  • Add to my manuals
  • Print
  • Page
    / 110
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 93
5-36
- IV Series Users Manual (Field Network) -
Operating procedure of the data I/O communication
Registering a master image for the IV series externally
Master registration request
Master registration response
BUSY
(1) Execute a [Master registration request]. (0 → 1)
(2) You can check the input status in [Master registration response].
[BUSY] will change from 0 to 1 while the master image registration is in progress.
If the master image registration is unsuccessful, [Master registration failed] will change from 0 to 1.
If the master image registration is unsuccessful, [Warning] will switch from “0” to “1” and [Warning No.]
will be updated according to the failure details. For details, refer to
“Warning code list” (Page 5-30).
You cannot register a master image from the PROFINET communication while the unit is in “Setting”
status.
If you wish to write the master registration data to the sensor ROM, set the [Write to ROM at external
master reg.] option to [Yes]. For details of the setting, refer to the “IV Series User’s Manual (Monitor /
PC Software)”.
5
Data I/O communication
Page view 93
1 2 ... 89 90 91 92 93 94 95 96 97 98 99 ... 109 110

Comments to this Manuals

No comments