5-8
- IV Series Users Manual (Field Network) -
Data I/O communication setting method
6
Install the GSDML le if you are
conguring the IV series for the rst time.
Select [Install general station description le
(GSD)] from the [OptIOns] menu.
Select the GSDML le for the IV series you
wish to install, and then click the [Install]
button.
Restart TIA Portal V11 after the installation.
The GSDML le for the IV series can be
downloaded from the KEYENCE web site.
http: //www.keyence.co.jp
7
Open [Other eld devices] - [PROFINET
I/O] - [Sensors] - [KEYENCE
CORPORATION] - [Keyence Vision
Sensors] from [Hardware catalog] on the
[Devices] - [Device & networks] screen,
and then drag & drop [IV-xxxx].
8
Connect the PLC with the IV series by
mouse operation.
If the connection is successful, the following
information will appear.
9
Double-click the IV series’ icon on the
[Device & networks] screen.
The [IV] screen will appear.
10
Enter the same character string as the
PROFINET device name of the IV series to
be connected.
5
Data I/O communication