Keyence IV Series User Manual Page 84

  • Download
  • Add to my manuals
  • Print
  • Page
    / 110
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 83
5-26
- IV Series Users Manual (Field Network) -
Data allocations in the data I/O communication
z
Device Status Words Address 0 to 15: Error/status/status result information
The Bits at Address 0 to 15 of the Device Status Words have the following functions:
Address
Data
type*
Item Content Data content
0 to 1 WORD Error code
Displays the currently occurring
error code.
0 to 128
2 to 3 WORD Warning code
Displays the currently occurring
warning code.
0 to 128
4 to 5 WORD
Number of remaining
buffers
Displays the number of status
results that can be buffered, if
handshake control is [Enabled].
0 to 10
6 to 7 WORD Checksum
Displays the current sensor
setting status using an arbitrary
5-digit integer.
0 to 65535
8 to 9 WORD Current program No.
Displays the current program
No.
0 to 31
10 to 11 WORD
Program No. during
judgment
Displays the program No. of the
latest judgment process.
0 to 31
12 to 13 WORD Result No.
Displays the judgment process
counts.
0 to 32767
14 to 15 WORD Processing time
Displays the processing time of
the latest judgment process.
0 to 10000
* WORD : Unsigned 16-bit integer
DWORD : Unsigned 32-bit integer
y
The unit of processing time is msec.
y
If two or more errors are occurring at the same time, the error code of the highest priority error will be
displayed.
“Error code list” (Page 5-29)
y
The rst occurred warning code will be displayed.
“Warning code list” (Page 5-30)
y
A checksum can be used to monitor whether the sensor settings have been modied by a third party.
y
The checksum will remain unchanged even if you switch programs.
y
The checksum will remain unchanged even if you change the IP address, subnet mask, default gateway
or port number of the IV series.
y
For the number of remaining buffers, refer to “Reading out the overall status result of the IV series
(Handshake control [Enabled])” (Page 5-34).
y
The upper limit value of the result No. is 32767. If the maximum value is exceeded, it will go back to 0
and start counting up again.
y
The result No. will also count the judgment process counts that were skipped due to the real-time
communication cycle setting.
5
Data I/O communication
Page view 83
1 2 ... 79 80 81 82 83 84 85 86 87 88 89 ... 109 110

Comments to this Manuals

No comments