Keyence IV Series User Manual Page 86

  • Download
  • Add to my manuals
  • Print
  • Page
    / 110
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 85
5-28
- IV Series Users Manual (Field Network) -
Data allocations in the data I/O communication
Tool Result Modules parameter details
Position Adjust Result Address 0 to 19 (Position correction information)
The Bits at Address 0 to 19 of the Position Adjust Result have the following functions:
Address
Data
type*
Item Content Data content
0 to 1 WORD
Position correction tool
matching rate
Stores the matching rate of the
position correction tool.
0 to 100
2 to 3 WORD
Position correction tool
Matching rate MAX
Stores the maximum matching
rate value of the position
correction tool.
0 to 100
4 to 5 WORD
Position correction tool
Matching rate MIN
Stores the minimum matching
rate value of the position
correction tool.
0 to 100
6 to 7 WORD
Position correction tool
Threshold value
Stores the threshold value of the
position correction tool.
0 to 100
8 to 19 --- Reserved by system --- ---
* WORD : Unsigned 16-bit integer
DWORD : Unsigned 32-bit integer
Maximum and minimum matching rate values of the position correction tool will be reset in the same
manner as the statistics information.
Tool Result Address 0 to 19 (Tool information)
The Bits at Address 0 to 19 of the Tool Result have the following functions:
Address
Data
type*
Item Content Data content
0 to 1 WORD Tool 1 matching rate
Stores the matching rate of Tool 1.
0 to 999
2 to 3 WORD
Tool 1 matching rate MAX
Stores the maximum matching
rate value of Tool 1.
0 to 999
4 to 5 WORD Tool 1 matching rate MIN
Stores the minimum matching
rate value of Tool 1.
0 to 999
6 to 7 WORD Tool 1 lower limit value
Stores the lower threshold value
of Tool 1.
0 to 999
8 to 9 WORD Tool 1 upper limit value
Stores the upper threshold
value of Tool 1.
0 to 999
10 to 19 --- Reserved by system --- ---
* WORD : Unsigned 16-bit integer
DWORD : Unsigned 32-bit integer
Thereafter, the information of tool 2, 3, ... 16 will be assigned for each 20-byte Address of “Tool Result”.
Maximum and minimum matching rate values of the tool will be reset in the same manner as the
statistics information.
If the upper threshold value of the tool is not set, the data content of the tool’s upper limit value will be “65535”.