Keyence DL-CL1 User Manual Page 30

  • Download
  • Add to my manuals
  • Print
  • Page
    / 72
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 29
3-2
3
Communicating with the FD-MH series
- CC-Link Compatible Network Unit DL-CL1 User’s Manual (FD-MH) -
3-1
CC-Link Communication and Operating Modes
The DL-CL1 operates as a remote device station of a CC-Link system.
This section describes the data that the DL-CL1 can exchange through the CC-Link,
and available operating modes.
The DL-CL1's data is linked with the CC-Link maser station as shown below.
Through the link, the CC-Link master station is enabled to:
Communicate the output signal, current value, an
d error status of sensor amplifiers
without the need of a ladder program.
Use the remote input RX and remote outpu t RY areas as handshake signals to
execute external inputs to, or change the setting values of, sensor amplifiers.
Execute motion commands on sensor amplifiers.
Directly read and write the parameters of sensor amplifiers. This capability gives
the ability to use functions that can be executed on sensor amplifiers.
Data Exchanged by Cyclic Transfer
(1) RX (Remote inputs)
(3)
RWr (Remote registers)
(2) RY (Remote inputs)
(4)
RWw (Remote registers)
Output
Current value
Error information
Read parameter
Request to change setting value
Changed setting value
External input
Write parameter
CC-Link master station DL-CL1
Sensor amplifier
Output
Current value
・・・・・・
・・・・・・
・・・・・・
・・・・・・
・・・・・・
Errror information
設定値
外部
Output
Current value
・・・・・・
・・・・・・
・・・・・・
・・・・・・
・・・・・・
・・・・・・
Errror information
設定値
外部
Output
Current value
・・・・・・
・・・・・・
・・・・・・
・・・・・・
・・・・・・
Error information
Setting value
External input
Read/write parameters
Page view 29