4
Settings for Advanced Functions
4-4
- Digital Fiber Sensor FS-N10 Series User's Manual -
4-2
Basic Settings
The detection stability will increase when the response time is delayed.
Yo u can select from the following 6 power modes.
The response time slows down in the order of hSP, FinE, turb, Supr, ULtr, MEGA.
Detection distance varies depending on the fiber units to be combined. For specific
numerical values, refer to the catalogues and specifications of the fiber units
concerned.
When using the unit in point-blank range, raising the power mode exces-
sively may attenuate the received light intensity. In such a case, either
lower the power mode or use the saturation Canceling function.
"Light emission/Received light intensity adjustment (Saturation
Canceling)" (page 3-18)
Yo u can select from the following 3 sensitivity setting methods.
* Refer to the followi
ng 2 pages for details.
Power Modes
Refer to page 4-2 "Basic Settings" for setting methods.
Display Power mode name Response time
hSP
HIGH SPEED mode 50 µs
FinE FINE mode (Default) 250 µs
turb TURBO mode 500 µs
SuPr SUPER mode 1 ms
ULtr ULTRA mode 4 ms
MEGA MEGA mode 16 ms
Point
Sensitivity Setting
Refer to page 4-2 "Basic Settings" for setting methods.
Display Sensitivity setting method
Reference
page
Std Normal sensitivity setting (without correction) (Default) 3-5 to 3-14
SEtP Percentage calibration 4-5
0SEt Zero shift calibration 4-6