4-6 2-output Settings ( )
4
Settings for Advanced Functions
4-38
- Digital Fiber Sensor FS-N10 Series User's Manual -
There are 3 types of timers available.
* The above charts show operation examples in the light-ON (L-on) mode for the
reflective model and in the dark-ON (d-on) mode for the retro-reflective or thru-
beam model.
Different output timers and different timer times can be set separately for
channels 1 and 2.
"Output Timer" (page 4-7)
The timer can only control on/off switching of the sensor output.
Output Timer for Output2
Refer to page 4-3 "2-output Settings ( )" for setting methods.
Display Function
Timing chart
*
toFF Uses no output timer. (Default)
oFFd
Off-delay timer
Turns off the output at a specified
time after the detection signal
goes off.
Setting range: 1 to 9999 ms
Default: 10 ms
on-d
On-delay timer
Turns on the output at a specified
time after the detection signal
goes on. Useful if the ON duration
is limited because the workpiece
is shaky such as by vibration.
Setting range: 1 to 9999 ms
Default: 10 ms
Shot
One-shot timer
Turns on the output and keeps it
on for a specified period after the
detection signal goes on.
Setting range: 1 to 9999 ms
Default: 10 ms
OFF
ON
With workpiece Without workpieceWithout workpiece
Control output
Timer-set period
OFF
ON
With workpiece Without workpieceWithout workpiece
Control output
Timer-set period
OFF
ON
With workpiece Without workpieceWithout workpiece
Control output
Timer-set period
OFF
ON
With workpiece Without workpieceWithout workpiece
Control output