Settings for Advanced Functions
4-35
- Digital Fiber Sensor FS-N10 Series User's Manual -
4-6
2-output Settings ( )
*This function is only available for the 2-output type models (FS-N13 / N14).
*1 If output 2 is set to Std, the DATUM1, DATUM2, area detection, and edge detection
modes are disabled in output 2.
*2 You can select the USEr (user reset) or Auto (auto reset) resetting methods after
outputting the limit setting under the following restriction:
-If output 1 is set to the DATUM1 mode or DATUM2 mode when LiMt is selected,
the detection will be performed with the value prior to DATUM calibration.
-If output 1 is set to the area detection mode or edge detection mode, LiMt can-
not be selected with output 2.
Detection Mode for Output2
Refer to page 4-3 "2-output Settings ( )" for setting methods.
Display Function
Std (Standard)
*1
Received-light intensity judgment mode (usual mode)
(Default)
LiMt (Limit)
*2
Limit setting output mode (Output 2 turns on if received
light intensity for output 1 decreases).
"Limit setting output mode" (page 4-36)
ALrt (Alert)
Warning output mode (Output 2 turns on when an error
occurs).
"Warning output mode" (page 4-37)