4-4 Display Settings (diSP)
4
Settings for Advanced Functions
4-26
- Digital Fiber Sensor FS-N10 Series User's Manual -
Timing chart for standard setting (Std)
[Peak value]
Samples while the current received light inten-
sity > setting value ((1), (3), etc.).
If the current received light intensity is lower
than the setting value, the previous peak
value is updated.
[Bottom value]
Samples while the current received light inten-
sity < setting value ((2), (4), etc.).
If the current received light intensity is higher
than the setting value, the previous bottom
value is updated.
Timing chart for peak value
[Cumulative maximum peak value]
Samples while the current received light inten-
sity > setting value ((1) to (4)).
If the current received light intensity is lower than
the setting value, the previous peak value and
current peak value are compared. If the current
peak value is higher, the value is updated.
[Cumulative minimum peak value]
Samples while the current received light inten-
sity > setting value ((1) to (4)).
If the current received light intensity is lower than
the setting value, the previous peak value and
current peak value are compared. If the current
peak value is lower, the value is updated.
Timing chart for bottom value
[Cumulative maximum bottom value]
Samples while the current received light
intensity < setting value ((1) to (4)).
If the current received light intensity is higher
than the setting value, the previous bottom
value and current bottom value are com-
pared. If the current bottom value is higher,
the value is updated.
[Cumulative minimum bottom value]
Samples while the current received light
intensity < setting value ((1) to (4)).
If the current received light intensity is higher
than the setting value, the previous bottom
value and current bottom value are com-
pared. If the current bottom value is lower, the
value is updated.
Received light intensity
Setting value
Received light
intensity
Peak value
Bottom value
(2)
(1) (3)
(4)
Received light intensity
Setting value
Received light
intensity
Cumulative maximum
of peak
Cumulative minimum
of peak
(2)(1) (3) (4)
Received
light intensity
Setting value
Received light intensity
Cumulative maximum
of bottom
Cumulative minimum
of bottom
(2)
(1) (3)
(4)
Page view 71