4-5 System Settings (SYS)
4
Settings for Advanced Functions
4-33
- Digital Fiber Sensor FS-N10 Series User's Manual -
Malfunction may result from "interference", a phenomenon in which light transmission
occurs simultaneously with any other sensor amplifier.
However, when the number of sensor amplifiers increases, the light transmission
timing automatically shifts and prevents this interference.
Setting this function to "dobL" (Double) on all of the connected amplifier units doubles
the number units that do not mutually interfere.
Selecting "dobL" also doubles response time over the "Std" state.
When selecting "dobL", the main unit and its connected expansion
units must all be set to "dobL".
This function cannot be set if the eco function is set to “FuLL
(Full)”.
Maximum number of interference prevention units
Number of units prevented from interference during the connection of the main and
expansion units of the FS-N10 Series is as follows.
Reference: Interference prevention is enabled even if connected to models
other than the FS-N10 Series. For the number of units for interference pre-
vention, please contact us.
Interference Prevention
Refer to page 4-2 "System Settings (SYS)" for setting methods.
Display Function
Std (Standard) Normal operation (Default)
dobL (Double)
The interference prevention doubles over the Standard
state.
Point
Power mode
Std
(Standard:
Normal
operation)
dobL
(Double:
Doubling of
interference
prevention units)
When the eco
function is
set to “Full”
hSP (HIGH SPEED) 0 unit 0 unit 0 unit
FinE (FINE) 4 units 8 units
16 units
turb (TURBO)
SuPr (SUPER)
ULtr (ULTRA)
MEGA (MEGA)
8 units 16 units
Reference