4-4 Display Settings (diSP)
4
Settings for Advanced Functions
4-24
- Digital Fiber Sensor FS-N10 Series User's Manual -
Displaying a sub display
After selecting the
desired sub-screen dis-
play, press the [MODE]
button twice in the normal
display state (setting
value / received light
intensity).
Press the [MODE] button
once again to return to
the normal display.
Extension display
The received light intensity usually displayed with 4 digits can be extended to a 5-digit
display.
The maximum received light intensity value which can be displayed differs according
to the power mode and display gain. Refer to "Display Gain" (page 4-32) for more
details.
•The upper limit of the setting value remains a 4-digit value (9999). A
larger value cannot be set.
Each preset function, zero shift function, and each calibration function
cannot be used during the extension display.
•The received light intensity calibrated with each preset function, zero
shift function, each DATUM mode or edge detection mode is not applied
on the extended display.
Bar display
Received light intensity can be displayed as a
bar graph.
Bars are displayed in real time in the range of
85% to 115% at intervals of 5%, where 100%
is the setting value.
Up to 8 bars are displayed.
Setting value/Received light intensity
Select L-on/D-on
MODE
MODE MODE
No operation for 3
sec or more
Sub-display
Refer to page 4-2 "Display Settings (diSP)" for setting methods.
Refer to page 4-2 "Display Settings (diSP)" for setting methods.
Display example
If the setting value is 1000: