3-2 Device Maps
3-14
- CC-Link Compatible Network Unit DL-CL1 User’s Manual (FD-MH) -
Communicating with the FD-MH series
3
Number [n] denotes the first relay number assigned to the DL-CL1.
*1 See "Entering an External Input into a Sensor Amplifier" (page 3-17).
*2 See "Reading/Writing Settings or Status of a Sensor Amplifier" (page 3-21).
See "Issuing a Motion Command to a Sensor Amplifier" (page 3-20).
*3 See "Rewriting a Setting Value of a Sensor Amplifier" (page 3-21).
Remote Register RWr (DL-CL1 -> Master Station)
Operating
mode
Device no.
(HEX)
Name
Communication
method
Description Reading range
Monitor mode 2
Full mode 1
Full mode 2
RWr[n] + 00 Error code -
Stores an error code when error state (RX[n]
+ 0F) turns ON.
*4
RWr[n] + 01
Command
response
*2
Used when communicating under handshake
control program.
Stores details of command execution result.
*5
RWr[n] + 02
to 03
(2 words)
Read data *2
Used when communicating under handshake
control program.
Stores the parameter data read from the
sensor amplifi er.
The data type
depends on the
parameter type.
RWr[n] + 04
Integration reset
input response
*1
Stores the integration reset input response of
the sensor amplifi er.
The response is output by assigning sensor
amplifi ers (ID 01 to ID 10) to bits 0 - 9.
0: Input OFF
1: Input ON
RWr[n] + 05
Flow rate hold
reset input
response
*1
Stores the fl ow rate hold reset input response
of the sensor amplifi er.
The response is output by assigning sensor
amplifi ers (ID 01 to ID 10) to bits 0 - 9.
0: Input OFF
1: Input ON
RWr[n] + 06 (Not used) - - -
RWr[n] + 07
Temperature
hold reset input
response
*1
Stores the temperature hold reset input
response of the sensor amplifi er.
The response is output by assigning sensor
amplifi ers (ID 01 to ID 10) to bits 0 - 9.
0: Input OFF
1: Input ON
RWr[n] + 08 (Not used) - - -
RWr[n] + 09
Current value
"invalid"
*3
If instantaneous fl ow rates from sensor
amplifi ers (ID 01 to ID 10) are invalid (-----),
they are output by assigning them to bits 0 - 9.
0: Normal value
1: Invalid
RWr[n] + 0A
Current value
"over"
*3
If instantaneous fl ow rates from sensor
amplifi ers (ID 01 to ID 10) are "over"(FFFF),
they are output by assigning them to bits 0 - 9.
0: Normal value
1: Over
RWr[n] + 0B
Current value
"under"
*3 Not used with the FD-MH series. -
RWr[n] +0C
to 0D
(INT32)
Current Value
ID01
*3
Used for reading the instantaneous fl ow rate
value.
Outputs the instantaneous fl ow rate value of
the sensor amplifi er (ID 01).
INT32 (LITTLE)
RWr[n] +0E
to 0F
(INT32)
Current Value
ID02
*3
Used for reading the instantaneous fl ow rate
value.
Outputs the instantaneous fl ow rate value of
the sensor amplifi er (ID 02).
INT32 (LITTLE)
RWr[n] +10
to 11
(INT32)
Current V
alue
ID03
*3
Used for reading the instantaneous fl ow rate
value.
Outputs the instantaneous fl ow rate value of
the sensor amplifi er (ID 03).
INT32 (LITTLE)
Page view 41