Keyence LS-3100/3100W Series User Manual Page 62

  • Download
  • Add to my manuals
  • Print
  • Page
    / 104
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 61
56
CHAPTER 4 Functions and Controls
Function Command Description
TF? Outputs preset value of LOW1 for
7-level differentiation
I? Outputs whether comparator output
is set to ON or OFF
T? Outputs differentiation level (3- or
7-level)
AS? Outputs preset value for analog
output voltage scaling
A? Outputs preset value for number of
measurements for averaging
B? Outputs averaging method (simple
or sequential )
U? Outputs measurement unit
( "mm" or "inch" ).
J? Outputs setting information for
HOLD/AUTO ZERO function.
Z? Outputs whether AUTO ZERO
function is set to ON or OFF.
HO? Outputs whether HOLD function
is set to ON or OFF.
C? Outputs which arithmetic operation
method is set
M? Outputs measurement mode
H? Outputs preset upper tolerance limit
for 3-level differentiation
L? Outputs preset lower tolerance limit
for 3-level differentiation
O? Outputs preset OFFSET value
G? Outputs preset number of deleted
display digits
Specifying and
outputting setting
information
ls3100_49_64.p65 08.10.1, 10:56 AM56