6-1 Bar LED Indicator
6-3
Indicators
6
SL-V-M-NO6-E
When the detection zone is interrupted. (one or more beam axis is blocked.)
The states of the 5 bar LEDs are as follows:
No.5 will light up red so long as the top beam axis is uninterrupted.
No.2 through 4 will light up red so long as the top and bottom beam axis are uninterrupted.
No.1 will light up red so long as the bottom beam axis is uninterrupted.
The display is the same for the transmitter and the receiver.
Indication pattern
OSSD keeps ON state in case of muted or override condition, but the indication is in accordance with the above pattern.
In case of series connection, the indicators on each unit independently indicate according to their own situation.
See "Series Connection" (page 2-6)
Applying the fixed blanking function to a beam reverses the clear and blocked results for that beam.
See "Fixed Blanking" (page 2-48)
When the detection zone is uninterrupted
The states of the 5 bar LEDs will light up green and indicate the number of beam axis with an amount of
received light being 140% or greater.
Indication pattern
For the definition of the amount of receiving light of 100%, 100% means a threshold between OSSD-ON and OSSD-OFF.
In case of around 100%, the light curtain easily goes to ON state or OFF state due to environmental or installation factor,
such as dust, pollution, angle, vibration or the like.
In order to make suitable operation of the SL-V, the SL-V should be operated with all of bar LEDs No.1 to No.5 lit in green,
even though the SL-V is able to do the normal operation with the amount of receiving light of 100% or more.
OSSD keeps OFF state during interlock condition even if no interruption is present in the detection zone.
In case of series connection, the indicators on each unit independently indicate according to their own situation.
See "Series Connection" (page 2-6)
During normal operation
Indication
Top beam axis
Blocked
(Interrupted)
Blocked
(Interrupted)
Clear
(Not interrupted)
Clear
(Not interrupted)
Bottom beam axis
Blocked
(Interrupted)
Clear
(Not interrupted)
Blocked
(Interrupted)
Clear
(Not interrupted)
OSSD state OFF OFF OFF OFF
OFF
5
OFF
4
OFF
3
OFF
2
OFF
1
OFF
5
OFF
4
OFF
3
OFF
2
Red
1
Red
5
OFF
4
OFF
3
OFF
2
OFF
1
Red
5
Red
4
Red
3
Red
2
Red
1
NOTE
Indication
Description
The amount of receiving light for all
beam axes are 100% or more, but
less than 140%. This state is not
stable for operation.
The amount of receiving
light for all beam axes
are 100% or more, and
that of any one beam
axis is 140% or more.
The amount of receiving
light for all beam axes
are 100% or more, and
that of any two beam
axes are 140% or more.
The amount of
receiving light for
almost all beam axes
are 140% or more.
OSSD state
ON ON ON ON
OFF
5
OFF
4
OFF
3
Green
2
Green
1
OFF
5
OFF
4
OFF
3
OFF
2
OFF
1
OFF
5
OFF
4
Green
3
Green
2
Green
1
OFF
5
Green
4
Green
3
Green
2
Green
1
Green
5
Green
4
Green
3
Green
2
Green
1
NOTE