Keyence SL-V Series User Manual Page 38

  • Download
  • Add to my manuals
  • Print
  • Page
    / 168
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 37
2-14
Functions and Features
2
SL-V-M-NO2-E
2-5 AUX (Auxiliary) Output
The AUX (Auxiliary) output is a NON-SAFETY-RELATED function.
This output just informs an external device (non safety-related device) of the operations of the SL-V and
operates in synchronization with OSSD operation. It can only be connected to a PLC or similar non-safety
devices.
The AUX output is not allowed to be used as a safety output for safety-related control
systems. This output does not constitute a part of the safety-related control system. Usage
of this function as a safety output may result in significant harm to the machine operators
including injury or death.
Wiring
Output rating : 26.4 V DC or less, 50 mA or less
Regardless of if you are using an NPN or a PNP cable, the SL-V AUX output can be connected to PNP
and NPN devices. Refer to the time charts mentioned in this manual because the AUX output logic is dif-
ferent depending on the connected device.
Time chart
(1) When using a PNP output cable to connect to a PNP input device,
or when using an NPN output cable to connect to an NPN input device
(2) When using a PNP output cable to connect to an NPN input device,
or when using an NPN output cable to connect to a PNP input device
Danger
Input device
Brown
Red(AUX output)
Blue
0V
+24V
Trans-
mitter
Main
circuit
0V
+24V
Trans-
mitter
Main
circuit
Brown
Red(AUX output)
Blue
Input device
For connecting a PNP input device For connecting an NPN input device
NOTE
50 ms max. 50 ms max.
(1)
ON
OFF
(2)
ON
OFF
ON
OFF
OSSD
AUX
Page view 37
1 2 ... 33 34 35 36 37 38 39 40 41 42 43 ... 167 168

Comments to this Manuals

No comments