Keyence IV Series User Manual Page 77

  • Download
  • Add to my manuals
  • Print
  • Page
    / 110
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 76
5-19
- IV Series Users Manual (Field Network) -
Data allocations in the data I/O communication
Tool Result Modules (IV series→ PLC)
Tool Result Modules are modules that write responses from the IV series to the PLC.
The device map of the data allocated for the Tool Result Modules is as shown below.
Stores the matching rate and threshold information of the position correction and other tools.
For details of each parameter, refer to “Tool Result Modules parameter details” (Page 5-28).
Position Adjust Result
Slot No.: 6
Module size: 20 bytes
Address Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0
0 - 1 Position correction score (Unsigned 16-bit data)
2 - 3 Position correction score MAX (Unsigned 16-bit data)
4 - 5 Position correction score MIN (Unsigned 16-bit data)
6 - 7 Position correction score Lower threshold (Unsigned 16-bit data)
8 - 19 Reserved by system
Tool Result
Slot No.: 7 to 22
Module size: 20 bytes
Address Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0
0 - 1 Tool score (Unsigned 16-bit data)
2 - 3 Tool score MAX (Unsigned 16-bit data)
4 - 5 Tool score MIN (Unsigned 16-bit data)
6 - 7 Tool lower threshold (Unsigned 16-bit data)
8 - 9 Tool upper threshold (Unsigned 16-bit data)
10 - 19 Reserved by system
5
Data I/O communication
Page view 76
1 2 ... 72 73 74 75 76 77 78 79 80 81 82 ... 109 110

Comments to this Manuals

No comments