A-2
- IV Series Users Manual (Field Network) -
Reference program (EtherNet/IP)
This section introduces a reference program for when using EtherNet/IP communication in the IV series.
In the actual operation, programming must be performed taking the error processing, etc. into
consideration.
Handshake control [Disabled]
Keyence KV series
Line 1
Line 2
Line 3
Line 4
REQ Trigger response Trigger request
Result update
complete MOV
Tool score DM2000
Result update
complete
Trigger request
Result available
Description of the reference program
Line 1/Line 2
Sets “REQ” to ON and executes a trigger request.
“Trigger response” ON will set “Trigger request” to OFF (“Trigger request” is retained until “Trigger
response” is set to ON).
Line 3/Line 4
“Result available” ON + Rising or falling of “Result update complete” will copy the data that have been
written to the tool score to DM2000.
Reference program (EtherNet/IP)