- IV Series Users Manual (Field Network) -
Reference program (PROFINET)
Program switching
Siemens PLC
Network1
Network2
P
P
MOV
EN
IN
Program Number
ENO
OUT
Number
REQ
REQ
Program Change
Program ChangeProgram Change Ack
Description of the reference program
Network1
This line sets “REQ” to ON and copies the Number data, which contains the program No. to be set, to the
program No.
Network2
Sets “REQ” to ON and executes “Program Change”.
“Program Change Ack” ON will set “Program Change” to OFF (“Program Change” will be retained until
“Program Change Ack” becomes ON).