Keyence IV Series User Manual Page 34

  • Download
  • Add to my manuals
  • Print
  • Page
    / 110
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 33
3-12
- IV Series Users Manual (Field Network) -
Data allocation in the cyclic communication
Input Assembly parameter details
Input Assembly Address 0: Control result (response)
The Bits at Address 0 of the Input Assembly have the following functions:
Address Bit Item Content Data content
0
0 Trigger response
Stores the external trigger
response.
0 : OFF
1 : ON
1
Master image registration
response
Stores the master image
registration response.
0 : OFF
1 : ON
2
Program switching
response
Stores the program switching
response.
0 : OFF
1 : ON
3 Warning clear response
Stores the warning clear
response.
0 : OFF
1 : ON
4 Statistics reset response
Stores the statistics reset
response.
0 : OFF
1 : ON
5 Buffer clear response Stores the buffer clear response.
0 : OFF
1 : ON
6 to 7 Reserved by system --- ---
Input Assembly Address 1: Control error result
The Bits at Address 1 of the Input Assembly have the following functions:
Address Bit Item Content Data content
1
0 Trigger failed
This bit is output when the
external trigger is unsuccessful.
0 : -
1 : The external trigger
has failed.
1
Master image registration
failed
This bit is output when the
master image registration is
unsuccessful.
0 : -
1 :
Master image
registration has failed.
2 Program switching failed
This bit is output when
the program switching is
unsuccessful.
0 : -
1 : Program switching
has failed.
3 to 7 Reserved by system --- ---
3
Cyclic communication
Page view 33
1 2 ... 29 30 31 32 33 34 35 36 37 38 39 ... 109 110

Comments to this Manuals

No comments