5-13
- IV Series Users Manual (Field Network) -
Data I/O communication setting method
11
Open [PROFINET IO] - [Additional Field
Devices] - [Sensors] - [Keyence Vision
Sensors] from [Hardware Catalog] in the
[HW Cong] window, and then drag &
drop [IV-xxxx] onto [PROFINET-IO-System]
in the Station Window.
The IV series will be added to the Station
Window; and all modules available for the IV
series will be added automatically.
If [PROFINET-IO-System] is not displayed
on the Station Window, right-click [PN-IO]
of the CPU and select [Insert PROFINET IO
System].
12
Double-click the IV series icon in the [HW
Cong] window.
The [Properties - IV series] window will appear.
13
Enter the same character string as the
PROFINET device name of the IV series to
be connected into the [Device name] eld.
14
Click the [Ethernet] button.
The [Properties - Ethernet interface IV series]
window will appear.
15
Enter the IP address for the IV series to be
connected into the [IP address] eld.
16
Click the [OK] button to return to the [HW
cong] window.
5
Data I/O communication